Spectra (2 & 4 Zone) Fire Alarm Panels
Micro Controller Based 2 Zone Fire Alarm Panel Expandable Up to 4 Zones. Compact design good looking Panel.
- Fully Confirm IS 2189
- Zone Wise fire fault LED Indication.
- Zone Isolation Facility
- Mains on, System On, Charger on, visual indications.
- Auto dialler attachable facility
- External S/w for Reset, Silence, Lamp test.
- External s/w to test each zone fire, open, short status manually.
- Inbuilt Buzzer
- 16 × 2 Line LCD Display.
- Inbuilt Battery Charger & Battery Space.
- Operates on 230 VAC, 50 Hz AC supply.
- Potential Free Contact Facility
Power I/P | 230 V.AC / 24 V DC |
Power Consumption | 30 Watt/200 Watt (Normal/Fire) |
End Of Line | 4 K7 |
No. Of Zones | 2,4 |
Detection O/P Supply | 24 V DC |
Hooter O/P Supply | 24 V DC |
Operating Temperature | 00 C to 40 0 C |
Operating Humidity | 95% (Non Condensing) |
Cabinet Type | MS |
Colour | Off White |
Paint | Powder Coating |
Knock Out | 20 mm |
Dimension | 11"× 13" × 4" |
Weight | 5.2 Kg. Without Battery |
Fire Alarm Control Panels
Bulwark (6 & 8 Zones) Fire Alarm Panel
Micro controller based 6 zone fire alarm panel expandable up to 8 zones. Compact design good looking panel.
- Fully confirm IS 2189.
- Zone wise fire fault LED indication.
- Zone isolation facility
- Mains on, System on, Charger on, Visual indications.
- Auto dialler attachable facility
- External s/w for reset, Silence, Lamp test.
- External s/w to test each zone fire, open, short status manually.
- Inbuilt Buzzer.
- 16 × 2 Line LCD Display
- Inbuilt battery charger & battery space.
- Operates on 230 V AC, 50 Hz AC supply
- Potential free contact facility
Power I/P | 230 V.AC / 24 V DC (Optional) |
Power Consumption | 30 Watt/200 Watt (Normal/Fire) |
End Of Line | 4 K7 |
No. Of Zones | 6,8 |
Detection O/P Supply | 24 V DC |
Hooter O/P Supply | 24 V DC |
Operating Temperature | 00 C to 40 0 C |
Operating Humidity | 95% (Non Condensing) |
Cabinet Type | MS |
Colour | Off White |
Paint | Powder Coating |
Dimension | 11"× 13" × 4" |
Weight | 7.2 Kg. Without Battery |
Fire Alarm Control Panels
Bulwark (10 To 48 Zones) Fire Alarm Panels
Micro controller based 10 zone fire alarm panel expandable up to 48 zones. Compact design good looking panel
- Fully confirm IS 2189.
- Zone wise fire fault LED indication.
- Zone Isolation Facility.
- Mains on, System on, Charger on, Visual indications.
- Auto dialler attachable facility.
- External s/w for reset, Silence, Lamp test.
- External s/w to test each zone fire, open, short status manually.
- Inbuilt Buzzer.
Power I/P | 230 V.AC / 24 V DC (Optional) |
Power Consumption | 45 Watt/450 Watt (Normal/Fire) |
End Of Line | 4 K7 |
No. Of Zones | 10 - 16 |
Detection O/P Supply | 24 V DC |
Hooter O/P Supply | 24 V DC |
Operating Temperature | 00 C to 40 0 C |
Operating Humidity | 95% (Non Condensing) |
Cabinet Type | MS |
Colour | Red |
Paint | Powder Coating |
Dimension | 16.5"× 14" × 5" |
Weight | 15 Kg. Without Battery |
PA Console Panel
Microprocessor Based Panel With PA System
- Modular design, plug in type solid state.
- Expandable up to 2 to 50 zone fire alarm panel.
- Each zone with fire, short indication & sound.
- Associate with P.A. System, Talk back system, Auto dialer etc.
- Battery charger & Battery box facility.
- Mains, AC fail, Rev. Battery, Fuse blown, Fault isolate indication.
- Compatible with any make automatic detector.
- zone wise selector with all call cacility.
- Geoseneck Microphone attached.
- music player attachable facility.
- Modular design, Plug in type solid state.
- Battery charger & battery box facility.
- Zone wise selector with all calls facility.
- Microphone attached.
- Music Player attachable facility.
Gas Release Panels
- New attractive look with zone wise LED & LCD indication.
- Two mode selection facility (Auto/Manual) with cross zoning
- Gas Inhibition and instant release facility.
- Feather touch switched for auto/manual mode selection, manual release, manual abort, disable operations.
- Inbuilt battery charger & battery space facility.
- Up / Down switch for delay time setting.
- SOV line monitoring facility and line status through LED display.
- 7 - segment display for discharged delay time setting.
- Key lock for enabling and disbling of control switches.
- Common fire, fault and pre - discharge potential free contacts.
Sprinkler Annunciation Panel
- Fully microprocessor based digital panel.
- 2 to 200 zone expandable facility.
- Zone wise window facility.
- Reset, Silent & Lamp test facility.
- Compatible with all type of flow switches.
- Extra potential free contact facility.
Talk Back Master Panel
- Customised talk back master station.
- Used for two way communication.
- Simplex type talk back with connectivity.
- 5 to 50 zone expandable.
- Simple operation (Press to talk facilities).
- Talk back panel as per IS standards.
- Best used in multistoried building.
Fire Pump Control Panels
- Easy to Operate
- Maintenance free
- Longer working life
- High performance
- Auto / Manual function
Application | Protection & control of power distribution |
Operational Current | 4000A |
Operational Voltage | 415v |
Rated Insulation | 690v |
Ambient Temperture | 45 0C |
Degree of Protection | As per IS standard |
Type test performed | Short circuit withstand temp rise withstand degree of protection |
Configuration | Fixed Type |
Enclosure Type | Indoor / Outdoor |
Bus Bar | Electrolytic grade aluminiu / copper |
Housing | 14/16SWG |
Fire Pump Control Panels
- Remote control operation facility.
- MCCB for protection.
- Change over switch for circuit change from mains to DC and vice-versa.
- Direct on line starters that includes MCB, Contactor, thermal overload relay and connectors.
- Properly rated bus bars duly covered with acrylic sheet for safety.
- GIstrip for earthing.
- Fan for ventilation.
- Simple operation.
- Minimum maintenance.
- Feeds larger loads.
- Multiple power stabs.
- Durable & rust resistant.
Fire Pump Control Panels
- Auto / Manual function available.
- Reset, Accept, Mute functions available.
- Start fail signal available.
- Trickle / Boost charging available.
- Auto cut off battery charging available.
- Over speed, LLOP, HWT, Audio / Visual signal available.
- Alarm facilities.
- Wall mounting / floor mounting available.
- Manual starts / stop function available.
LT Panel
- Easy to operate
- Maintenance free
- Longer working life
- High performance
Starter Panel
- DOL Starter
- Star - Delta starter
- Auto - Transformer starter
- Soft Starter
- Three phase and single phase starter available
- Easy installation and connections
- Operational voltage - 415 V.
- Wall mounting / Floor mounting available
Fire Rated Doors
Fire Rated Wooden Doors (in 1hr. & 2 hr.)
Doors are approved from central building research institute (CBRI Roorkee) 120 Minuts Rated Composite Wooden Fire / Smoke Check Door
- Wooden door frame of hard wood / teak wood of section 120 mm × 70 mm with heat activated intumescent fire stip of section 15mm × 4mm and one coat of fire and anti-termite primer.
- 50mm thick asbestos free composite fire / smoke check wooden shutters of 120 minutes fire resistance rating comprising of two 12mm thick calcium silicate board sandwiching 25mm thick proprietary fire resistance insulation material faced with 3mm thick commercial ply facing on bath sides with heat activated intumescent fire seal strip size 15mm × 4mm mounted in the grooves on three sides except bottom and one coat of anit - termite fire retardant primer.
Fire Rated Steel Doors (in 2hr.)
Steel Doors are approved from department of Industries & Commerce, Bahadurgarh (Haryana)
60 / 120 Minutes Fire Rated Steel Door
- 46mm thick steel fire door of 60 / 120 minutes fire rating fabricating with 2 no. 18SWG galvanized steel sheet sandwiching with proprietary fire resistant insulation material in between. The door frames are manufactured from 16SWG galvanized steel sheet. Pressed form to double reabate profile of size 143mm × 57mm. The door frame and door shutter are fitted with SS ball bearing Hinges (extra cost) and are coated with one coat of fire and corrosion resistant primer.
Fire Rated Door Accessories