Smoke Detector Fire Alarms

We are Manufacturer, Supplier, Dealer, Traders of Smoke Detector Fire Alarms, Spectra (2 & 4 Zone) Fire Alarm Panels, Fire Alarm Control Panels, PA Console Panel, Gas Release Panels, Fire Alarm And Accessories, Fire Pump Control Panels, Diesel Engine Control Panels Emergency Exit Lights, Fire Rated Doors and our setup is situated in Pune, Maharashtra, India.

  • Spectra (2 & 4 Zone) Fire Alarm Panels
  • Fire Alarm Control Panels
  • PA Console Panel
  • Gas Release Panels
  • Fire Alarm And Accessories
  • Fire Pump Control Panels
  • Diesel Engine Control Panels
  • Emergency Exit Lights
  • Fire Rated Doors
Spectra (2 & 4 Zone) Fire Alarm Panels

Spectra (2 & 4 Zone) Fire Alarm Panels

Micro Controller Based 2 Zone Fire Alarm Panel Expandable Up to 4 Zones. Compact design good looking Panel.

    Features :
  • Fully Confirm IS 2189
  • Zone Wise fire fault LED Indication.
  • Zone Isolation Facility
  • Mains on, System On, Charger on, visual indications.
  • Auto dialler attachable facility
  • External S/w for Reset, Silence, Lamp test.
  • External s/w to test each zone fire, open, short status manually.
  • Inbuilt Buzzer
  • 16 × 2 Line LCD Display.
  • Inbuilt Battery Charger & Battery Space.
  • Operates on 230 VAC, 50 Hz AC supply.
  • Potential Free Contact Facility
Technical Specification :
Power I/P 230 V.AC / 24 V DC
Power Consumption 30 Watt/200 Watt (Normal/Fire)
End Of Line 4 K7
No. Of Zones 2,4
Detection O/P Supply 24 V DC
Hooter O/P Supply 24 V DC
Operating Temperature 00 C to 40 0 C
Operating Humidity 95% (Non Condensing)
Technical Specification :
Cabinet Type MS
Colour Off White
Paint Powder Coating
Knock Out 20 mm
Dimension 11"× 13" × 4"
Weight 5.2 Kg. Without Battery
Fire Alarm Control Panels

Fire Alarm Control Panels

Bulwark (6 & 8 Zones) Fire Alarm Panel


Micro controller based 6 zone fire alarm panel expandable up to 8 zones. Compact design good looking panel.

    Features :
  • Fully confirm IS 2189.
  • Zone wise fire fault LED indication.
  • Zone isolation facility
  • Mains on, System on, Charger on, Visual indications.
  • Auto dialler attachable facility
  • External s/w for reset, Silence, Lamp test.
  • External s/w to test each zone fire, open, short status manually.
  • Inbuilt Buzzer.
  • 16 × 2 Line LCD Display
  • Inbuilt battery charger & battery space.
  • Operates on 230 V AC, 50 Hz AC supply
  • Potential free contact facility
Technical Specification :
Power I/P 230 V.AC / 24 V DC (Optional)
Power Consumption 30 Watt/200 Watt (Normal/Fire)
End Of Line 4 K7
No. Of Zones 6,8
Detection O/P Supply 24 V DC
Hooter O/P Supply 24 V DC
Operating Temperature 00 C to 40 0 C
Operating Humidity 95% (Non Condensing)
Technical Specification :
Cabinet Type MS
Colour Off White
Paint Powder Coating
Dimension 11"× 13" × 4"
Weight 7.2 Kg. Without Battery
Fire Alarm Control Panels

Fire Alarm Control Panels

Bulwark (10 To 48 Zones) Fire Alarm Panels


Micro controller based 10 zone fire alarm panel expandable up to 48 zones. Compact design good looking panel

    Features :
  • Fully confirm IS 2189.
  • Zone wise fire fault LED indication.
  • Zone Isolation Facility.
  • Mains on, System on, Charger on, Visual indications.
  • Auto dialler attachable facility.
  • External s/w for reset, Silence, Lamp test.
  • External s/w to test each zone fire, open, short status manually.
  • Inbuilt Buzzer.
Technical Specification :
Power I/P 230 V.AC / 24 V DC (Optional)
Power Consumption 45 Watt/450 Watt (Normal/Fire)
End Of Line 4 K7
No. Of Zones 10 - 16
Detection O/P Supply 24 V DC
Hooter O/P Supply 24 V DC
Operating Temperature 00 C to 40 0 C
Operating Humidity 95% (Non Condensing)
Technical Specification :
Cabinet Type MS
Colour Red
Paint Powder Coating
Dimension 16.5"× 14" × 5"
Weight 15 Kg. Without Battery
PA Console Panel

PA Console Panel

Microprocessor Based Panel With PA System

    Features :
  • Modular design, plug in type solid state.
  • Expandable up to 2 to 50 zone fire alarm panel.
  • Each zone with fire, short indication & sound.
  • Associate with P.A. System, Talk back system, Auto dialer etc.
  • Battery charger & Battery box facility.
  • Mains, AC fail, Rev. Battery, Fuse blown, Fault isolate indication.
  • Compatible with any make automatic detector.
  • zone wise selector with all call cacility.
  • Geoseneck Microphone attached.
  • music player attachable facility.
PA Console Panel
    Features :
  • Modular design, Plug in type solid state.
  • Battery charger & battery box facility.
  • Zone wise selector with all calls facility.
  • Microphone attached.
  • Music Player attachable facility.
Gas Release Panels

Gas Release Panels

    Features :
  • New attractive look with zone wise LED & LCD indication.
  • Two mode selection facility (Auto/Manual) with cross zoning
  • Gas Inhibition and instant release facility.
  • Feather touch switched for auto/manual mode selection, manual release, manual abort, disable operations.
  • Inbuilt battery charger & battery space facility.
  • Up / Down switch for delay time setting.
  • SOV line monitoring facility and line status through LED display.
  • 7 - segment display for discharged delay time setting.
  • Key lock for enabling and disbling of control switches.
  • Common fire, fault and pre - discharge potential free contacts.
Gas Release Panels

Sprinkler Annunciation Panel

    Features :
  • Fully microprocessor based digital panel.
  • 2 to 200 zone expandable facility.
  • Zone wise window facility.
  • Reset, Silent & Lamp test facility.
  • Compatible with all type of flow switches.
  • Extra potential free contact facility.
Gas Release Panels

Talk Back Master Panel

    Features :
  • Customised talk back master station.
  • Used for two way communication.
  • Simplex type talk back with connectivity.
  • 5 to 50 zone expandable.
  • Simple operation (Press to talk facilities).
  • Talk back panel as per IS standards.
  • Best used in multistoried building.
Fire Alarm And Accessories

Hooter ABS 1

Fire Alarm And Accessories

Hooter MS 1

Fire Alarm And Accessories

Hooter ABS 2

Fire Alarm And Accessories

Hoter ABS 3

Fire Alarm And Accessories

Smoke & Heat Detector

Fire Alarm And Accessories

Siren 220V AC

Fire Alarm And Accessories

MCP MS 1

Fire Alarm And Accessories

MCP ABS 1

Fire Alarm And Accessories

MCP ABS 2

Fire Alarm And Accessories

MCP ABS 3

Fire Alarm And Accessories

MCP ABS 4

Fire Alarm And Accessories

Duplex Talk back Unit

Fire Alarm And Accessories

Panic Switch

Fire Alarm And Accessories

Simplex Talk Back Unit

Fire Alarm And Accessories

Response Indicator

Fire Pump Control Panels

Fire Pump Control Panels

    Technical Specifications :
  • Easy to Operate
  • Maintenance free
  • Longer working life
  • High performance
  • Auto / Manual function
Application Protection & control of power distribution
Operational Current 4000A
Operational Voltage 415v
Rated Insulation 690v
Ambient Temperture 45 0C
Degree of Protection As per IS standard
Type test performed Short circuit withstand temp rise withstand degree of protection
Configuration Fixed Type
Enclosure Type Indoor / Outdoor
Bus Bar Electrolytic grade aluminiu / copper
Housing 14/16SWG
Fire Pump Control Panels

Fire Pump Control Panels

    Features :
  • Remote control operation facility.
  • MCCB for protection.
  • Change over switch for circuit change from mains to DC and vice-versa.
  • Direct on line starters that includes MCB, Contactor, thermal overload relay and connectors.
  • Properly rated bus bars duly covered with acrylic sheet for safety.
  • GIstrip for earthing.
  • Fan for ventilation.
  • Simple operation.
  • Minimum maintenance.
  • Feeds larger loads.
  • Multiple power stabs.
  • Durable & rust resistant.
Fire Pump Control Panels

Fire Pump Control Panels

    Features :
  • Auto / Manual function available.
  • Reset, Accept, Mute functions available.
  • Start fail signal available.
  • Trickle / Boost charging available.
  • Auto cut off battery charging available.
  • Over speed, LLOP, HWT, Audio / Visual signal available.
  • Alarm facilities.
  • Wall mounting / floor mounting available.
  • Manual starts / stop function available.
diesel engine control panel

LT Panel


    Features :
  • Easy to operate
  • Maintenance free
  • Longer working life
  • High performance
diesel engine control panel

Starter Panel


    Features :
  • DOL Starter
  • Star - Delta starter
  • Auto - Transformer starter
  • Soft Starter
  • Three phase and single phase starter available
  • Easy installation and connections
  • Operational voltage - 415 V.
  • Wall mounting / Floor mounting available
Spot Light (Beam Light)

Spot Light (Beam Light)

Exit LED Type

Exit LED Type 2

Exit LED Type

Exit LED Type 2

Exit Light Box Type

Exit Light Box Type

Exit Laser Type

Exit Laser Type

Flow Switch

Flow Switch

Fire Rated Doors

Fire Rated Doors

Fire Rated Wooden Doors (in 1hr. & 2 hr.)


Doors are approved from central building research institute (CBRI Roorkee) 120 Minuts Rated Composite Wooden Fire / Smoke Check Door

    Door Frame :
  • Wooden door frame of hard wood / teak wood of section 120 mm × 70 mm with heat activated intumescent fire stip of section 15mm × 4mm and one coat of fire and anti-termite primer.
  • Door Shutter :
  • 50mm thick asbestos free composite fire / smoke check wooden shutters of 120 minutes fire resistance rating comprising of two 12mm thick calcium silicate board sandwiching 25mm thick proprietary fire resistance insulation material faced with 3mm thick commercial ply facing on bath sides with heat activated intumescent fire seal strip size 15mm × 4mm mounted in the grooves on three sides except bottom and one coat of anit - termite fire retardant primer.
Fire Rated Doors

Fire Rated Steel Doors (in 2hr.)


Steel Doors are approved from department of Industries & Commerce, Bahadurgarh (Haryana)

60 / 120 Minutes Fire Rated Steel Door

  • 46mm thick steel fire door of 60 / 120 minutes fire rating fabricating with 2 no. 18SWG galvanized steel sheet sandwiching with proprietary fire resistant insulation material in between. The door frames are manufactured from 16SWG galvanized steel sheet. Pressed form to double reabate profile of size 143mm × 57mm. The door frame and door shutter are fitted with SS ball bearing Hinges (extra cost) and are coated with one coat of fire and corrosion resistant primer.

Fire Rated Door Accessories

Fire Rated Door Accessories

Panicbar

Fire Rated Door Accessories

SS Ball Bearing hinges

Fire Rated Accessories
Fire Rated Accessories

Mortise lock with lever handle

Fire Rated Accessories

Deadlock

Fire Rated Accessories

Fire Rated Door Closer

Fire Rated Accessories

SS Handle D Type or H Type